Transmitting Data - Siemens SIMATIC S5 Manual

Interface of the programmable controller
Hide thumbs Also See for SIMATIC S5:
Table of Contents

Advertisement

S5-95U, SINEC L2
4.3

Transmitting Data

There are two prerequisites for transmitting data:
The parameters for the locations of SF and CBS are set in data block DB1 (see section 4.2).
The transmit data,
station address of the receiver) have been transferred to the send mailbox.
Figure 4-4 shows which information must be stored in which send mailbox location.
Example: Send mailbox in the flag area
(starting with flag byte 0)
FY 0
"Net data" length in bytes
(1 to 242)
*
FY 1
Receiver's address*
FY 2
1st data item
FY 243
242nd data item
*
1 to 31 = L2 station address (active stations)
255 = Broadcasting (to all active and passive stations, see section 4.6)
Figure 4-4. Structure of the Send Mailbox for a Standard Connection
EWA 4NEB 812 6112-02
additional information (length of the transmit data ("net data"), and the
Data Transmission Using a Standard Connection
Example: Send mailbox in the data block
(starting with data word DW0)
DL
DW 0
"Net data" length
in bytes (1 to 242)
DW 1
1st data item
DW 121
241st data item
--
DR
Receiver's
address*
2nd data item
242nd data item
4-5