Chapter 6
10. Release the plastic retaining mechanism (I/O Card Guide) that secures the end of the board
nearest the front of the chassis so that it will allow a board to be inserted
11. Be sure that the rocker switch that secures the end of the board nearest the rear of the chassis
is in the open position. If not, press the center of the rocker switch until it clicks open and then
rotate the mechanism downward from outside the chassis.
12. If you are adding a new board, remove the perforated rear panel cover in the slot you're using
by pushing it out from inside the chassis.
NOTE
13. Being careful not to touch the components or gold edge connectors on the add-in board,
remove it from its protective wrapper and place it component-side up on a nonconductive,
antistatic surface.
14. Record the serial number of the board in your equipment log. See Appendix B for the
equipment log.
15. Press the PCI adapter board down firmly until it seats in its slot.
16. Close the plastic latching mechanism (I/O Card Guide) that secures the end of the board
nearest the front of the chassis.
17. Rotate the rocker switch near the rear of the chassis up until it clicks into place.
18. Install the non-hot plug PCI adapter board cover by aligning the slotted hinge into the chassis
housing, closing the cover, and securing the cover screw.
19. Attach any cables to the PCI adapter board you just installed.
20. Close the rear part of the top cover and tighten the two thumbscrews.
21. Attach the power cords.
22. Push the system back into place into the equipment rack.
23. Power on any attached peripheral devices.
24. Power on the system.
Figure 31. Accessing the Non-Hot Plug Boards
Ensure you save the slot covers for use later to prevent EMI interference. These slot
covers make a better metal-to-metal contact than previous slot cover designs.
Replacing Parts