Self-Diagnosis Display; Execution Of Lens Shift Calibration; Code Table - Panasonic PT-DZ12000U Service Manual

Dlp based projector
Hide thumbs Also See for PT-DZ12000U:
Table of Contents

Advertisement

PT-DZ12000U / PT-DZ12000E / PT-D12000U / PT-D12000E / PT-DW100U / PT-DW100E
IGNORE: Does not control the shutter when power OFF.
· CINEMA FILTER
NONE: Default setting
INSTALLED: When installing the color filter that expands the color region
· AIR FILTER
NORMAL: Default setting
SPECIAL: Sets it when the smoke cut filter is installed.
· UNIFORMITY
Sets the value of color unevenness correction.
· FRONT LAMP LED
ON: Default setting
OFF: Prohibits a green lighting.
· LAMP CHANGE MUTE
ON: Turns off the projection temporarily when switching the lighting lamp.
OFF: Does not turn off the projection when switching the lighting lamp. However, a video noise might appear momentarily in the
projection.
· LENS SHIFT CALIBRATION
Calibrates the limit and the home position of the lens shift.
Execute LENS SHIFT CALIBRATION according to the procedure of the next paragraph when replacing the lens mount, LH-
Module or LV-Module.
· COOLING TIME
NORMAL: Sets all the cooling time to 240 seconds.
FAST: Default setting (Sets all the cooling time to 170 seconds.)
· MENU LOCK
ON: Sets the menu lock.
OFF: Default setting
· MENU LOCK PASSW ORD
Sets the password for the menu lock release. The default (initial password) is "AAAA".

4.3.11. Execution of LENS SHIFT CALIBRATION

1. Enter the serviceman mode according to the section 4.1. "Setting to Serviceman Mode".
2. Select LENS SHIFT CALIBRATION in EXTRA OPTION.
3. Press the ENTER button. When you execute LENS SHIFT CALIBRATION, press the ENTER button again when displayed
"SURE?".
4. The lens moves up/down/right/left, and the limit and the home position values of the shift are set again automatically.
5. When the lens stops, re-setting is finished.

5 Self-diagnosis Display

There is a self-diagnosis display located at the side of the projector which automatically displays their details when error, warning
or others occur.
If a code is displayed in the self-diagnosis display, check the part of the cause according to the content of the code table below.
5.1.

Code Table

Self-
diagnosis
display
U11
Temperature warning (IN)
U12
Temperature warning (OPT)
U13
Temperature warning (OUT)
U14
Low temperature warning (OPT)
Contents
Shutdown
Display condition
Intake air temperature is the specific value or
higher.
Optical module temperature is the specific
value or higher.
Lamp surroundings temperature is the specific
value or higher.
Optical module temperature is less than the
specific value.
14
Remarks