12.28. Removal of Analysis Mirror

Note:
· Before attempting the removing, shift the lens to the foremost position.
(1)
Remove the DMD block and liquid cooling unit according to the
section 12.27. "Removal of DMD Block and Liquid Cooling Unit".
(2)
Unscrew the 4 screws and remove the analysis mirror with
engine base.
(3)
Unscrew the 3 screws and remove the engine base.

12.29. Removal of Lens Mount Unit

Note:
· Before attempting the removing, shift the lens to the foremost position.
(1)
Remove the projection lens, DMD block, liquid cooling unit and
analysis mirror according to the section 12.28. "Removal of
Analysis Mirror".
(2)
Remove the synthesis block and analysis block according to the
steps 2 through 10 in the section 12.25. "Removal of Analysis
Block".
(3)
Unscrew the 4 screws and remove the lens mount unit.