Dell S5000 Deployment/Configuration Manual page 50

Deployment of a converged infrastructure with fcoe
Hide thumbs Also See for S5000:
Table of Contents

Advertisement

Dell Networking S5000: Deployment of a Converged Infrastructure with FCoE
/* Create FCoE VLAN */
> interface vlan 1003
> exit
/* Create FCoE MAP */
> fcoe-map SAN_FABRIC_B
> fabric-id 1003 vlan 1003
> fc-map 0efc01
> exit
/* Apply FCoE MAP to interface */
> interface fibrechannel 0/0
> fabric SAN_FABRIC_B
> no shutdown
Figure 52: Dell S5000 (fabric B) configuration
/* Apply FCoE MAP and DCB MAP to interface */
> interface tengigabitethernet 0/12
> dcb-map SAN_DCB_MAP
> fcoe-map SAN_FABRIC_A
/* Make server port an edge-port */
> protocol spanning-tree rstp edge-port
> no shutdown
> exit
In Figure 53 below you can see the output of the 'switchshow' command on the fabric A FC switch.
Notice that the port connected to the Dell S5000 switch (port 4) now states "F-Port 1 N Port + 1 NPIV
public." As the Dell S5000 switch is acting as a NPIV Proxy Gateway, it will always have only one
N_Port on this link, and the remaining connections through the link will cause the NPIV count to
increase.
50
Deployment of a Converged Infrastructure with FCoE
Deployment/Configuration Guide

Advertisement

Table of Contents
loading

Table of Contents