Dell Networking S5000: Deployment of a Converged Infrastructure with FCoE
Figure 65: Fabric A Dell S4810 (FSB) configuration
> enable
> config terminal
> dcb stack-unit 0 pfc-buffering pfc-ports 64 pfc-queues 2
> cam-acl l2acl 6 ipv4acl 2 ipv6acl 0 ipv4qos 2 l2qos 1 l2pt 0 ipmacacl 0 vman-qos 0 ecfmacl 0 fcoeacl 2
iscsioptacl 0
> exit
> write
> reload
> enable
> config terminal
> protocol spanning-tree rstp
> no disable
> exit
> dcb enable
> feature fip-snooping
> service-class dynamic dot1p
> interface tengigabitethernet 0/43
> portmode hybrid
> switchport
> fip-snooping port-mode fcf
> protocol lldp
> dcbx port-role auto-upstream
> no shut
> end
> config terminal
> interface tengigabitethernet 0/42
> portmode hybrid
> switchport
> protocol spanning-tree rstp
> protocol lldp
> dcbx port-role auto-downstream
> no shut
> end
> config terminal
> interface range fortyGigE 0/48 - 56
> port-channel-protocol lacp
> port-channel 20 mode active
> no shut
> exit
> interface port-channel 20
> switchport
> exit
> config terminal
> interface vlan 1002
> tagged tengigabitethernet 0/42
> tagged tengigabitethernet 0/43
> exit