Dell Networking S5000: Deployment of a Converged Infrastructure with FCoE
During initial configuration of the Compellent Storage Center, we created a disk pool labeled "Pool_1"
consisting of seven 300 GB drives. The total disk space is 1.64 TB; this can be seen in the screen shot
of the Storage Center System Manager GUI as shown below in Figure 5.
Figure 5: Storage Center System Manager GUI displays disk pool "Pool_1" with 1.64 TB free space
Since we have two fabrics, fabric A and fabric B, we create two fault domains. Domain 1 is already
created by default and all the FC ports are currently in domain 1. To create another domain click
'Storage Management' on the top left of the webpage and then select 'System->Setup->Configure
Local Ports'. Next, click the 'Edit Fault Domains' button at the bottom right of the dialog box. On the
next dialog box click the 'Create Fault Domain' button on the lower right of the dialog box. In the
'Name' field type a name for the new domain. In this case, we used "Domain 2". Make sure 'FC' is
selected in the 'Type' field and click 'Continue'. Figure 6 below shows that we have already created the
second domain.
Figure 6: Creating an additional Fault Domain on Compellent Storage Array
Now we can navigate back to the 'Configure Local Ports' dialog and select the appropriate Domain to
put each port in. Each fabric should be in its own Domain; we put all ports going to fabric A in Domain
1 and all ports going to fabric B in Domain 2 as shown below.
8
Deployment of a Converged Infrastructure with FCoE
Deployment/Configuration Guide