Commissioning Test
Confirmation of RSL
Confirmation of 15 Min Performance
3-14
Click Monitor > Radio Performance > Current
Radio Performance Current
Confirm Current value.
Item
Tx Level (dBm)
TX output power
Rx Level (dBm) Received Signal Level
If Rx Level current value is out of specification, do the trouble shooting.
Click Monitor > Radio Performance > 15 Minutes
Confirm 15 Minute performance.
Fujitsu and Fujitsu Customer Use Only
Parameter
Setting value +/- 3 dB
System design value +/- 3 dB
BroadOne GX4000 Manual (R3.0) issue 1.03
Specification