Factory Setting Of The Mode Selector; Commissioning Tools - Siemens SIWAREX WP231 Manual

Hide thumbs Also See for SIWAREX WP231:
Table of Contents

Advertisement

Commissioning

7.3 Factory setting of the mode selector

7.3
Factory setting of the mode selector
Two DIP switches are located on the left of the Ethernet connector (accessible through the
ventilation opening).
The left-hand switch
operating environment.
Switch position
Up
Down
The factory setting is "Operation integrated in SIMATIC".
Note
If the switch is set to the down position while the SIWAREX module is in operation with
SIMATIC, the SIWAREX module will not carry out a reset upon loss of power supply to the
SIMATIC CPU.
7.4

Commissioning tools

The following options are available for commissioning the electronic weighing system:
● Operator Panel
● SIWATOOL
The SIWATOOL program allows you to commission the scale without an Operator Panel and
without an automation system. In the event of a fault, additional SIWATOOL diagnostics
functions enable fast analysis of the cause.
44
currently has no function. The right-hand switch
Operating environment
Operation integrated in SIMATIC
Stand-alone operation (without SIMATIC controller)
defines the
SIWAREX WP231
Manual, 07/2014, A5E31238908A-02

Advertisement

Table of Contents
loading

Table of Contents