Hour Meter; Reel Drive Solenoid - Toro Reelmaster 3100-D Service Manual

Hide thumbs Also See for Reelmaster 3100-D:
Table of Contents

Advertisement

Hour Meter

1. Connect the positive (+) terminal of a 12 VDC source
to the positive terminal of the hour meter.
2. Connect the negative (−) terminal of the voltage
source to the other terminal of the hour meter.
3. The hour meter should move a 1/10 of an hour in six
minutes.
4. Disconnect the voltage source from the hour meter.

Reel Drive Solenoid

Note: Prior to taking small resistance readings with a
digital multimeter, short the test leads together. The me-
ter will display a small resistance value (usually 0.5
ohms or less). This resistance is due to the internal re-
sistance of the meter and test leads. Subtract this value
from from the measured value of the component you are
testing.
1. Make sure engine is off. Disconnect solenoid valve
electrical connector.
2. Apply 12VDC source directly to the solenoid. Listen
for solenoid to switch on.
3. Remove 12VDC source from the solenoid. Listen for
solenoid to switch off.
4. Measure resistance between the two connector ter-
minals. The resistance should be about 7.2 ohms.
5. Install new solenoid if necessary.
A. Make sure o−ring is installed at each end of coil.
Apply "Loctite 242" or equivalent to threads on end of
valve stem before installing nut.
B. Tighten nut to a torque of 15 in−lb (17.3 kg−cm).
Over−tightening may damage the solenoid or cause
the valve to malfunction.
6. Reconnect electrical connector to the solenoid.
Electrical Systems
1
1. Hydraulic manifold
Page 5 − 32
Hobbs
QUARTZ
1
0 0 0 0
1
10
HOURS
+
BACK
Figure 9
Figure 10
2. Solenoid
Reelmaster 3100−D
2

Hide quick links:

Advertisement

Table of Contents
loading