Standard Control Module - Toro Reelmaster 3100-D Service Manual

Hide thumbs Also See for Reelmaster 3100-D:
Table of Contents

Advertisement

Standard Control Module

Reelmaster 3100−D machines with Serial Numbers
above 240000000 are equipped with a Standard Control
Module to monitor and control electrical components re-
quired for safe operation. This Module is attached to the
back of the instrument panel.
Inputs from the neutral, parking brake, PTO, start (igni-
tion), backlap, and high temperature switches are moni-
tored by the Module. Output to the PTO (reel drive
solenoid), fuel pump, and engine run solenoid are con-
trolled based on the inputs received by the Module.
The Standard Control Module does not connect to an
external computer or hand held device, can not be re−
programmed, and does not record intermittent fault
data.
The Standard Control Module can be used to check op-
eration of machine switches by monitoring the LED of
the module. If a Module LED does not illuminate (e.g. the
in seat input LED does not illuminate with the seat occu-
pied and the ignition switch in the run position), testing
of the switch and circuit wiring would be required.
Refer to the Traction Unit Operator's Manual for opera-
tion and troubleshooting of the Standard Control Mod-
ule.
Reelmaster 3100−D
1
2
3
4
5
1. Power input LED
2. Start input LED
3. Engine run output LED
4. Start output LED
5. PTO output LED
Page 5 − 41
Figure 25
6. Neutral input LED
7. Park brake off input LED
8. PTO switch input LED
9. In seat input LED
10. High temp input LED
11. Backlap input LED