104
ACS800-U4 size
Three-phase supply voltage 525 V, 575 V or 600 V
-0011-7
-0016-7
-0020-7
-0025-7
-0030-7
-0040-7
-0050-7
-0060-7
-0070-7
-0100-7
-0120-7
-0145-7
-0175-7
-0205-7
*
Overload may be limited to 5% at high speeds (> 90% speed) by the internal power limit of the drive.
The limitation also depends on motor characteristics and network voltage.
**
Overload may be limited to 40% at high speeds (> 90% speed) by the internal power limit of the
drive. The limitation also depends on motor characteristics and network voltage.
*** Higher rating is available with special 4-pole high-efficiency NEMA motor.

Symbols

Nominal ratings
I
max
Normal use (10% overload capability)
I
2N
P
N
Heavy-duty use (50% overload capability)
I
2hd
P
hd
Note 1: The ratings apply in ambient temperature of 40°C (104°F). In lower temperatures the ratings
are higher (except I

Sizing

See page 93.

Derating

See page 94.
Technical data
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
I
Normal use
max
I
2N
A
A
14
11.5
19
15
28
20
38
23
44
30
54
34
68
46
84
52
104
73
124
86
172
108
190
125
245
155
245
192
maximum output current. Available for 10 s at start, otherwise as long as allowed by drive
temperature.
continuous rms current. 10% overload is typically allowed for one minute every 5 minutes.
typical motor power. The power ratings apply to most 4-pole NEMA rated motors (230 V,
460 V or 575 V).
continuous rms current. 50% overload is typically allowed for one minute every 5 minutes.
typical motor power. The power ratings apply to most 4-pole NEMA rated motors (230 V,
460 V or 575 V).
).
max
Heavy-duty use
P
I
P
N
2hd
hd
HP
A
HP
10
8.5
7.5
10
11
10
15/20*** 15
15**
20
20
20**
25/30*** 25
25**
30
30
30**
40
40
40**
50
42
40
60
54
50
75
62
60
100
86
75
125
99
100
150
131
125
200
147
150
Frame
Air flow
Heat
size
dissipation
3
ft
/min
BTU/Hr
R4
61
1050
R4
61
1200
R4
61
1550
R4
61
1850
R4
61
2100
R4
61
2400
R5
147
2900
R5
147
3450
R6
238
4200
R6
238
5650
R6
238
6700
R6
238
9100
R6
238
11900
R6
238
14300
PDM code: 00096931-J