WIRING REQUIREMENTS
The cooker MUST be installed in
compliance with:
• Wiring connections in AS/NZS 3000
Wiring Rules.
• Local regulations, municipal building
codes and other statutory regulations.
For New Zealand Only:
The cooking range must be connected to
the supply by a supply cord fitted with the
appropriately rated plug. This plug is to be
compatible with the socket-outlet fitted to
the final sub-circuit in the fixed wiring that
is intended to supply this cooking range.
Supply cord size required
BPK722910M - 4mm2
Data plate
• Disconnection in the fixed wiring must
occur in accordance with the AS/
NZS3000 wiring rule.
• The cooker requires a means of all pole
disconnection incorporated into the fixed
wiring. This MUST have a disconnection
gap of 3mm.
• The cooker MUST be properly earthed.
• This oven must be connected with cable
of 75°C rating minimum.
• This product has passed the insulation
resistance test after manufacture. If the
resistance reading is low at installation,
it is probably caused by moisture from
the atmosphere being absorbed by
the elements after the range has been
produced. (Pass at 0.01 MW AS/NZS
3000 Wiring Rules Clause 8.3.6.2).
NOTE: When connections are made to a multi-phase
230/240V supply, the bridge piece MUST be
removed from between the active connections.
gives information
about rating is located
behind the bottom of
the oven door
Rated Power Input
Model
BPK722910M
IMPORTANT!
Before you cook in your new oven
it is important that the protective oils
used in the manufacture of the product
be removed.
• Make sure that the room is well
ventilated (to allow smoke to escape).
• Run the grill on high for 30 minutes
without grill dish.
• Then run the oven on 220°C for 1 hour.
Connecting to services and
commissioning
This appliance must be installed by an
authorised person, according to all codes
and regulations of:
• Electrical supply authorities.
• Building regulations.
• Local government and council
authorities.
• AS/NZS 3000 (particular attention to
clause 4.3.11 and clause 3.9).
Hard wiring detail
1. Remove terminal cover plate from rear
panel of appliance.
2. Fit wires through hole in cover plate and
make connections to terminals.
3. Engage wires into plastic clip. Secure
plastic clip with two long silver screws
(supplied in separate bag).
4. Replace cover plate onto rear panel.
English
43
Total kW
5.5

Hide quick links: