Warnings - Siemens SINUMERIK 840D sl Operating Manual

Sinumerik integrate create myconfig - eplan electric p8 add-in
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

8.3

Warnings

List of the possible warnings for which feedback is available.
The warnings are listed in alphabetical order and are described.
Warnings
Description
BUS_DATA_IS_NOT_NUMERIC
The bus data has not been defined numerically.
BUS_SYSTEMID_IS_DIFFERENT
Two different PROFINET networks are defined at two con‐
nections of the device.
CONFIGURATION_COULD_NOT_READING / CONFIGURATION_UNAUTHORIZED_READING
The configuration could not be read.
CONFIGURATION_COULD_NOT_WRITING / CONFIGURATION_UNAUTHORIZED_WRITING
The configuration could not be written.
CONNECTION_HAS_SAME_DEVICE_ON_BOTH_ENDS
The connection goes to the same device.
CONNECTION_NOT_HOMOGEN
The connection is between different types, e.g. DRIVE-CLiQ
to Power.
CONNECTION_TO_UNKNOWN_DEVICE
The connection goes to an unknown device.
CONNECTION_TO_UNKNOWN_PORT
The connection goes to an unknown port.
DEVICE_EXISTS_MULTIPLE_TIME
The device has more than one EPLAN main function?
DEVICE_NOT_IN_DRIVECLIQ_TOPOLOGY
The DRIVE-CLiQ device is not contained in the DRIVE-CLiQ
topology.
DEVICE_ONLY_IN_POWERTOPOLOGY
The DRIVE-CLiQ device is only integrated in the power top‐
ology.
SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In
Operating Manual, 12/2017, A5E43099659B-AA
Remedy
In the "Properties (components): PLC connection points and
bus ports", enter a numeric value in the "Bus data" tab in the
"Position / Node ID" data filed for the single-pole PLC con‐
nector.
Unify the PROFINET data.
1. Correct the authorization error.
2. Delete the configuration files and save them again.
1. Correct the authorization error.
2. Delete the configuration files and save them again.
Change the connection to the correct device.
Change the connection.
The signaled device is unknown:
● Because not listed in the SINAMICS product catalog
● Not defined as unknown device
● Because no order number available
● No DRIVE-CLiQ type defined
Change the connection.
Or define the device as unknown device in order to specify
the port name and the type.
You can find further information in Section "Defining unknown
devices" (Page 19).
Select one EPLAN function as main function.
Integrate the device in the DRIVE-CLiQ topology.
Also integrate the device in the DRIVE-CLiQ topology.
Messages
8.3 Warnings
45

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d