Assembly
5.1 Installation
5.1.3

Machine installation

General
Note
In order to prevent the eyebolts loosening, after mounting, tighten these or remove them.
NOTICE
Damage to mounted components
Material damage can occur if you use the mounted components to help lift the motor.
Do not use the mounted components to help lift the motor.
● For vertical installation, use all of the eyebolts provided and when necessary, hoisting
straps (DIN EN 1492-1) and/or lashing straps (DIN EN 12195-2) to stabilize the position
of the motor.
● Prevent foreign bodies from falling into the fan cover. For vertical machine installation
with the shaft end facing downwards, attach a protective canopy.
● If the shaft extension is facing upwards, the user must prevent liquid from moving along
the shaft and entering the motor.
● Clean bare metal surfaces with anti-corrosion agent using white spirit to ensure proper
installation and / or machine mounting.
● Do not obstruct the ventilation! Do not draw in the discharged air directly – also from
adjacent equipment.
● Avoid exposing them to direct, intense solar radiation, rain, snow, ice, or also dust for
extended periods. Attach a covering structure or an additional cover when using or
storing outdoors.
● Do not exceed the permissible axial and radial forces.
● Only use explosion-protected machines in appropriate areas in accordance with directive
1999/92/EG .
If the certificate is supplemented by an X, observe the special conditions listed in the EC
type examination certificate. Special conditions for explosion-proof machines (Page 13)
● When installing electrical systems in hazardous zones, observe EN / IEC 60079-14 and
the corresponding country regulations.
● The machine temperature class specified on the rating plate must be equal to or greater
than the temperature class of any combustible gases that may develop.