Advertisement

Table 8- 2
Mechanical effects
Mechanical fault characteristics
Grinding noise
Overheating
Radial vibrations
Axial vibrations
Possible causes of faults
X
Rotating parts are grinding
X
Reduced air supply, fan possibly rotating in the wrong
direction
X
Rotor not balanced.
X
Rotor out of true, shaft bent
X
X
Poor alignment
X
Coupled machine not balanced
X
Surges from coupled machine
X
X
Imbalance originating from gearing
X
X
Resonance in the overall system (comprising machine
and foundation)
X
X
Changes in foundation
1) As well as eliminating the cause of the fault (as described under "Remedial measures"),
you must also rectify any damage the machine may have suffered.
2) Note any changes that take place while the temperature is rising.
Low-voltage motors
Operating Instructions, 05/2014, 5 610 00000 02 000
Remedial measures
1)
Determine cause and adjust parts concerned
Check airways, clean machine
Check feather key declaration (H, F, N)
Please consult the manufacturer.
Align machine set,
check coupling.
2)
Re-balance coupled machine
Inspect coupled machine
Adjust/repair gearing
Reinforce foundation following consultation
Determine cause of changes; eliminate if
necessary; realign machine