Pin Number Signal Name
3
SW (+)
4
L (+)
5
L2 (-)
6
SW (-)
I
2) Drawer kick-out drive signal
This signal outputs the pulses specified by the ESC p command.
The SW (+) state is checked by the host computer using the ESC u
command.
Electrical characteristics:
(a) Signal output current:
(b) Power supply output voltage:
(c) Power supply output current:
(d) Output waveform:
NOTES: 1. These are not output during printing.
2. Drawer kick-out drive signals L1 and L2 cannot be output at the same
time.
3. The resistance of the drawer kick-out solenoids should be 24
more. Otherwise, the overcurrent could damage the solenoids.
4. Be sure to use the power supply (pin 4) of the drawer kick-out
connector for the drawer kick-out solenoid power source.
3) Drawer open/close signal
SW (+) signal level:
NOTE: Do not connect anything otherthan a solenoid to the drive signal terminal
of the drawer kick-out connector.
Sender
Connected to:
Cash
Cash drawer
Printer
Cash drawer
Printer
Cash drawer
Cash drawer
-----
I
Maximum -1 A (510 ms or less)
24 VDC (typical)
Maximum 1 A (510 ms or less)
Refer to Figure B-l
"LOW = 0 to 0.5 V
"HIGH" = 3 to 5 V
66
Function
drawer
Connected to the (+) side of
the open/close detection
switch on the cash drawer.
Pulled up through a 10 k
resistor on the printer side.
+24 VDC for drawer kick-out
is supplied.
Drawer kick-out drive signal
L2.
Connected to the (-) side
of the open/dose detection
switch on the cash drawer.
Connected to the signal
ground on the printer side.
or