Analog Input Terminals 10 / 11 (Analog Selectable Input 3); Analog Input Terminals 103 / 104 (Main Actual Value); P741 Normalization For "Main Actual Value”; P744 Source For Selection Of Sign Reversal At "Main Actual Value" Analog Input - Siemens 6RA70 Series Instructions Manual

Microprocessor-based converters from 15a to 1680a for variable speed dc drives
Hide thumbs Also See for 6RA70 Series:
  • Faq (4 pages)
Table of Contents

Advertisement

PNU
Description

Analog input terminals 10 / 11 (analog selectable input 3)

P731
Normalization of "Analog selectable input 3"
This parameter specifies the percentage value which is generated for an
FDS
input voltage of 10V (or an input current of 20mA) at the analog input.
The following generally applies:
(G114)
For voltage input:
[%] =
P
731
10
V
With current input:
[%] =
P
731
20
mA
P732
Offset for "Analog selectable input 3"
(G114)
P733
Mode of signal injection at "Analog selectable input 3"
*
0 = Injection of signal with sign
1 = Injection of absolute value of signal
(G114)
2 = Injection of signal with sign, inverted
3 = Injection of absolute value of signal, inverted
P734
Source for selection of sign reversal at "Analog selectable input 3"
*
Selection of binector to control sign reversal at the analog input ("1" state
= reverse sign)
(G114)
0 = binector B0000
1 = binector B0001
etc.
P735
Filtering time for "Analog selectable input 3"
Note: Hardware filtering of approximately 1 ms is applied as standard.
(G114)
P736
Source for enabling of "Analog selectable input 3"
*
Selection of binector to control enabling of the analog input ("1" state =
enabled)
(G114)
0 = binector B0000
1 = binector B0001
etc.

Analog input terminals 103 / 104 (main actual value)

P741
Normalization for "Main actual value"
FDS
Rated value of input voltage at n max (=tachometer voltage at maximum
speed)
(G113)
This parameter defines the maximum speed when P083=1.
P742
Offset for "Main actual value" analog input
(G113)
P743
Mode of signal injection at "Main actual value" analog input
*
0 = Injection of signal with sign
1 = Injection of absolute value of signal
(G113)
2 = Injection of signal with sign, inverted
3 = Injection of absolute value of signal, inverted
P744
Source for selection of sign reversal at "Main actual value" analog
*
input
Selection of binector to control sign reversal at the analog input ("1" state
(G113)
= reverse sign)
0 = binector B0000
1 = binector B0001
etc.
P745
Filtering time for "Main actual value" analog input
Note: Hardware filtering of approximately 1 ms is applied as standard.
(G113)
10-74
Y
X .. Input voltage in volts
X
Y .. % value which is generated for input
voltage X
Y
X .. Input current in mA
X
Y .. % value which is generated for input
current X
Value range
[Unit]
Steps
-1000.0 to 1000.0
[%]
0.1%
-200.00 to 199.99
[%]
0.01%
0 to 3
1
All binector numbers
1
0 to 10000
[ms]
1ms
All binector numbers
1
-270.00 to 270.00
[V]
0.01V
-200.00 to 199.99
[%]
0.01%
0 to 3
1
All binector numbers
1
0 to 10000
[ms]
1ms
SIEMENS Energy & Automation
SIMOREG DC Master Base Drive Panel Operating Instructions
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: 4
P052 = 3
FS=100.0
P051 = 40
Type: I2
Online
Ind: None
P052 = 3
FS=0.00
P051 = 40
Type: I2
Online
Ind: None
P052 = 3
FS=0
P051 = 40
Type: O2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: O2
Online
Ind: None
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
Ind: 4
P052 = 3
FS=60.00
P051 = 40
Type: I2
Online
Ind: None
P052 = 3
FS=0.00
P051 = 40
Type: I2
Online
Ind: None
P052 = 3
FS=0
P051 = 40
Type: O2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: O2
Online