General Visualization Parameters - Siemens 6RA70 Series Instructions Manual

Microprocessor-based converters from 15a to 1680a for variable speed dc drives
Hide thumbs Also See for 6RA70 Series:
  • Faq (4 pages)
Table of Contents

Advertisement

PNU
Description
10.2

General visualization parameters

r001
Display of terminals 4 and 5 (main setpoint)
(G113)
r002
Analog input, terminals 103 and 104 (main actual value)
(G113)
r003
Analog input, terminals 6 and 7 (selectable input 1)
(G113)
r004
Analog input, terminals 8 and 9 (selectable input 2)
(G114)
r005
Analog input, terminals 10 and 11 (selectable input 3)
(G114)
r006
Analog output, terminals 14 and 15
Display of output value before normalization and offset
(G115)
r007
Analog output, terminals 16 and 17
Display of output value before normalization and offset
(G115)
r008
Analog output, terminals 18 and 19
Display of output value before normalization and offset
(G116)
r009
Analog output, terminals 20 and 21
Display of output value before normalization and offset
(G116)
r010
Display of status of binary inputs
Representation on operator panel (PMU):
(G110)
Segment ON:
Segment OFF:
Segment or bit
0 ....... Terminal 36
1 ....... Terminal 37 (switch-on)
2 ....... Terminal 38 (operating enable)
3 ....... Terminal 39
4 ....... Terminal 40
5 ....... Terminal 41
6 ....... Terminal 42
7 ....... Terminal 43
8 ....... Terminal 211
9 ....... Terminal 212
10 ....... Terminal 213
11 ....... Terminal 214
12 ....... Safety shutdown (E-Stop is applied) 1)
13 ....... (not used)
14 ....... (not used)
15 ....... (not used)
1) The safety shutdown command is applied (segment dark) if
- terminal XS-105 is open (switch operation, see also Section 9)
or
- terminal XS-107 (Stop pushbutton) is opened briefly and terminal XS-
108 (Reset pushbutton) is not yet activated (pushbutton operation,
see also Section 9)
SIEMENS Energy & Automation
SIMOREG DC Master Base Drive Panel Operating Instructions
15
14
13
12
11
10
9
6
4
7
5
3
2
1
0
Corresponding terminal is activated
(HIGH level is applied)
Corresponding terminal is not activated
(LOW level is applied)
Value range
[Unit]
Steps
-200.0 to 199.99
[%]
0.01%
-200.0 to 199.99
[%]
0.01%
-200.0 to 199.99
[%]
0.01%
-200.0 to 199.99
[%]
0.01%
-200.0 to 199.99
[%]
0.01%
-200.0 to 199.99
[%]
0.01%
-200.0 to 199.99
[%]
0.01%
-200.0 to 199.99
[%]
0.01%
-200.0 to 199.99
[%]
0.01%
8
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: None
P052 = 3
Type: I2
Ind: None
P052 = 3
Type: I2
Ind: None
P052 = 3
Type: I2
Ind: None
P052 = 3
Type: I2
Ind: None
P052 = 3
Type: I2
Ind: None
P052 = 3
Type: I2
Ind: None
P052 = 3
Type: I2
Ind: None
P052 = 3
Type: I2
Ind: None
P052 = 3
Type: I2
Ind: None
P052 = 3
Type: V2
10-7