Figure 2-7 Options For The Electronic Box - Siemens Micromaster 440 Operating Instructions Manual

0.12 kw - 250 kw
Hide thumbs Also See for Micromaster 440:
Table of Contents

Advertisement

2 Installation
2.3.2
Installation of options in the electronic box,
Frame Sizes FX and GX
The front cover of the MICROMASTER 440 is designed so that the control module
(normally the SDP) is almost flush with the opening in the front cover.
If more than one option is to be installed in the electronic box, it is necessary to
position the entire electronic box further to the rear
Figure 2-7
Installing the options
! Remove the front cover:
• Unscrew two screws at the bottom side of the front cover.
• Lift front cover up and out.
! Remove retaining screws on the electronic box.
! Screw on electronic box in correct installation position as shown in Figure 2-7
! Install additional options.
! Reinstall front cover.
30
Options for the electronic box
Installation position 2
Installation position1
Standard installation
Standard installation
Installation position1
Installation position 2
MICROMASTER 440
Operating Instructions
6SE6400-5AW00-0BP0
Issue 12/02