Panasonic 2WAY Multi Technical & Service Manual page 151

Troubleshooting. gas heat pump, air conditioner.
Hide thumbs Also See for 2WAY Multi:
Table of Contents

Advertisement

Indoor Unit Setting: No. 6 (Level 0) <  >
Key operation is used for indoor unit settings (operation impossible when connecting the water heat exchanger).
1) Indoor unit setting display (Level 0)
Shows menu selected indoor unit status display.

2) Outdoor unit setting item select operation (Level 1)
Pressing the SET (S007) key in the indoor unit setting display mode activates the following display.
(Occurs only upon completion of initial communication)
Example :  (Example: Indoor No. 1 unit, data code 1, with gas tube valve)
Operating the UP (S005) and DOWN (S006) keys in this mode makes it possible to select setting categories.
Pressing the HOME (S004) key or conducting no operations for 10 minutes activates a return to the HOME
display.
3) Outdoor unit setting operation (Level 2)
Setting start operation method
Setting change operation method : After entering the setting start operation mode, operating the UP (S005)
Setting confi rm operation method : After entering the setting start operation or setting change operation
Setting cancel operation method
(Setting details will not be cancelled when pushing the HOME (S004) key for more than 1 second during
indoor unit setting item select operation.)
4) Outdoor unit setting list
Data code
1
Indoor unit setting 1
(indoor unit 1)
2
Indoor unit setting 2
3
Indoor unit setting 3
4
Indoor unit setting 4
5
Indoor unit setting 5
6
Indoor unit setting 6
7
Indoor unit setting 7
8
Indoor unit setting 8
9
Indoor unit setting 9
A
Indoor unit setting A
B
Indoor unit setting B
C
Indoor unit setting C
D
Indoor unit setting D
E
Indoor unit setting E
F
Indoor unit setting F
G
Indoor unit setting G
H
Indoor unit setting H
I
Indoor unit setting I
J
Indoor unit setting J
K
Indoor unit setting K
L
Indoor unit setting L
N
Indoor unit setting N
: Press the SET (S007) key for one second in the setting data code select
mode.
This activates the forced setting in progress display. (TEST/WARNING
LED light)
and DOWN (S006) keys make it possible to change the setting details
of the selected setting categories.
completed, press the SET (S007) key for one second. This cancels the
forced setting in progress display, returning to indoor unit setting item
select operation. (TEST/WARNING LED off)
: "Pushing the HOME (S004) key for 1 second before setting confi rm
operation returns operation to normal."
Data
0/1 (Gas tube valve present/absent)
0= Lowest priority to 4= Highest priority
0/1 (Normal/Drain pump intermittent control)
0/1 (Normal/Drain pump continuous control)
0/1 (Normal/No cool air prevention control with heater thermostat-off)
0/1 (Normal/No air speed control with heater thermostat-off)
0/1 (Normal/No heater high-pressure avoidance control)
0/1 (Normal/Heater stop indoor frost prevention control)
0/1 (Normal/No refrigerant discharge control with heater thermostat-off)
0/1 (Normal/Air speed lower limit with heater thermostat-on LL)
0 to 8 (Cooling indoor fan odor compensation)
0/1 (Normal/Air speed select when dry thermostat off LL ↔ stop)
0 to 120 (Heating thermostat on upper limit:0,4,...480step)
0 to 120 (Heating thermostat on lower limit:0,4,...480step)
0 to 120 (Initial heating discharge:0,4,...480step)
0 to 120 (Initial cooling thermostat on:0,4,...480step)
0 to 120 (Heating high pressure avoidance:0,4,...480step)
0 to 120 (Cooling thermostat on lower limit:0,4,...480step)
0 to 120 (Heating thermostat off:0,4,...480step)
0 to 120 (Cooling thermostat off oil recovery:0,4,...480step)
-35 to 92 (Cooling discharge temperature:0= depending on model type,
-35 to 92°C)
-35 to 92 (Heating discharge temperature:0= depending on model type,
-35 to 92°C)
V–32
Remarks