HUAWEI MU609 HSPA LGA Module
Application Guide
module's temperature is lower than 100° C, the module disables thermal
protection: turns on its RF transmission, and presents the ^THERM: 0 indication.
When the module's temperature reaches 100° C, the module automatically shuts
down.
Notes:
Issue 02 (2013-09-18)
During an emergency call, if thermal protection is enabled, the module will present an
indication but will not take thermal protection actions such as turning off its RF or shutting
down.
After thermal protection is enabled, users cannot make emergency calls.
Thermal protection is designed to protect the module from being damaged by
overtemperature. To work in high temperature environments, both the module and its
peripheral components must be able to resist the same temperature.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Thermal Protection Application Scenarios
91