Extended functions
Automatic restart function (vector)
Commissioning
1. Activate function
-- Automatic restart: set mode (p1210)
-- Flying restart: Activate function (p1200)
2. Set start attempts (p1211)
3. Set waiting times (p1212, p1213)
4. Check function
Automatic restart status signals
The individual status signals for the automatic restart function are available in
r1214 (word and bit serial) for display and interconnection purposes.
A detailed description of the status signals can be found in:

References:

Important parameters (see List Manual)
S p1210
S p1211
S p1212
S p1213
S r1214
4-180
/LH1/
SINAMICS S120 List Manual
Automatic restart mode
Automatic restart, start attempts
Automatic restart, delay time start attempts
Automatic restart, monitoring time line supply return
CO/BO: Automatic restart, status
© Siemens AG, 2005. All rights reserved
SINAMICS S120 Function Manual, 06/05 Edition