Supply
Basic Infeed
Overview of key parameters for Basic Infeed (see List Manual)
S r0002
S r0046
S p0210
S p0840
S p0844
S r0898
S r0899
S r2138
S r2139
Function diagram overview (see List Manual)
S 8720
S ...
S 8760
1.3.2

Basic Infeed open-loop control

Description
The Basic Line Module can be controlled via the BICO interconnection by means
of terminals or the field bus. The operating status is indicated on the operating dis-
play r0002. The missing enable signals for operation (r0002 = 00) are mapped in
parameter r0046. The EP terminals (enable pulses) must be connected in accor-
dance with the Equipment Manual.
Acknowledge error
Errors that are still present but the causes of which have been rectified can be ac-
knowledged by means of a 0 --> 1 edge at the "Acknowledge error" (p2103.5) sig-
nal.
1-34
Infeed/operating display
CO/BO: Infeed missing enable signals
Device supply voltage
BI: ON/OFF1
BI: 1. OFF2
CO/BO: Control word sequential control infeed
CO/BO: Status word sequential control infeed
CO/BO: Control word faults/alarms
CO/BO: Status word faults/alarms 1
Control word sequential control infeed
Messages and monitoring functions