Basic Infeed Open-Loop Control - Siemens SINAMICS S120 Function Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Remedy
● activate the V
– Vector control: p1240 = 1 (factory setting)
– Servo control: p1240 = 1
– U/f control: p1280 = 1 (factory setting)
● Inhibit V
– Vector control: p1240 = 0
– Servo control: p1240 = 0 (factory setting)
– U/f control: p1280 = 0
● Activate the V
– Vector control: p1240 = 4 or 6
– Servo control: p1240 = 4 or 6
– U/f control: p1280 = 4 or 6
3.2.1

Basic Infeed open-loop control

Overview
The Basic Line Module can be controlled via a BICO interconnection, e.g. using terminals or
fieldbus. The operating status is indicated on the operating display r0002. The missing enable
signals for operation (r0002 = 00) are mapped in parameter r0046. The EP terminals (enable
pulses) must be connected in accordance with the manual of the corresponding power units.
Description
The Basic Line Module can be controlled via a BICO interconnection, e.g. using terminals or
fieldbus. The operating status is indicated on the operating display r0002. The missing enable
signals for operation (r0002 = 00) are mapped in parameter r0046. The EP terminals (enable
pulses) must be connected in accordance with the manual of the corresponding power units.
Acknowledging faults
Faults that are still present but the causes of which have been rectified can be acknowledged
using a 0/1 edge at the "1st acknowledge faults" signal (p2103).
Drive functions
Function Manual, 06/2019, 6SL3097-5AB00-0BP2