Safety Integrated Basic Functions
11.9 Control via TM54F
The actuator connected to the F-DO can also be tested under specific conditions as part of
forced checking procedure (test stop). See Chapter "Forced checking procedure or test of the
switch-off signal paths (test stop) for Safety Integrated Basic (Page 640)".
Table 11-7
Module
TM54F
F-DO signal sources
A drive group contains several drives with similar characteristics. The groups are
parameterized at the p10010 and p10011 parameters.
The following signals are available for interconnecting (p10042, ..., p10045) each one of the
four drive groups with the F-DO:
● STO active
● SS2 active
● SLS active
● Safe State
● Active SLS level bit 0
● SDI positive active
● SLP active
● Internal event
The following safe state signals can be requested via p10039[0...3] for each drive group (index
0 corresponds to drive group 1 etc.):
● STO active (power removed/pulse deleted) ● SS1 active
● SS2 active
● SLS active
● SDI positive active
Figure 11-7
The same signals (high-active) of each drive or drive group are logically linked by means of
AND operation. The different signals selected via p10039 are logically OR'ed. Result of these
670
Overview of the fail-safe outputs in the SINAMICS S120/S150 List Manual:
Function diagram
2895
Safe state selection (example Extended Functions)
Outputs
F-DO 0 ... 3
● SS1 active
● SOS active
● SSM feedback active
● SOS selected
● Active SLS level bit 1
● SDI negative active
● Active SLP area
● SOS active
● SLP active
● SDI negative active
Function Manual, 06/2019, 6SL3097-5AB00-0BP2
Associated checking in‐
puts
DI 20 ... 23
Drive functions