Basic functions
8.30 Parallel connection of motors
reference current (p2002). Parameter p0306 has a value range of 1 to 50, and is it dependent
on the motor data set (MDS).
1. To connect motors in parallel, select the corresponding motor in the selection screen and
activate the "Parallel motor connection" option.
2. Enter the number of motors in the parallel connection in the entry field "Number".
This display and input function is available for vector control only. For servo control, the
parallel connection of motors can only be configured using the expert list (parameter p0306).
Motors with integrated DRIVE-CLiQ interface (SINAMICS Sensor Module Integrated) can also
be connected in parallel. The first motor is connected to DRIVE-CLiQ via the encoder. The
additional motors must be identical. Using parameter p0306 and the encoder information
obtained via DRIVE-CLiQ, it is possible to determine all the necessary motor data.
Figure 8-22
420
Parallel motor connection selection for vector control