Basic information about the drive system
14.6 Inputs/outputs
Properties
● Separate power supply for the digital outputs.
● Source of output signal can be selected by parameter.
● Signal can be inverted by parameter.
● Status of output signal can be displayed
– As a binector output
– As a connector output
Note
Before the digital outputs can function, their own electronics power supply must be connected.
Function diagrams (see SINAMICS S120/S150 List Manual)
TB30
● 9102
TM31
● 9556
Control Unit 310-2
● 2038
Bidirectional digital inputs/outputs
Signal processing using the bidirectional inputs/outputs is shown in the function diagrams listed
below.
Properties
● Can be parameterized as digital input or output.
● When set as digital input:
– Six "high-speed inputs" on Control Unit
– The properties of the "pure" digital outputs apply.
● When set as digital output:
– The properties of the "pure" digital outputs apply.
● Sharing of bidirectional input/output resources by the CU and higher-level controller (see
Section "Use of bidirectional inputs/outputs on the CU (Page 801)")
800
Terminal Board 30 (TB30) -
isolated digital inputs (DI 0 ... DI 3)
Terminal Module 31 (TM31) -
Digital relay outputs, electrically isolated (DO 0 ... DO 1)
CU310-2 input/output terminals -
digital output (DO 16)
If these inputs are used, for example, for the "flying measurement" function, they act as
"high-speed inputs" with virtually no time delay when the actual value is saved.
Function Manual, 06/2019, 6SL3097-5AB00-0BP2