Safety Integrated Basic Functions
11.11 Acceptance test and acceptance report
Unsafe operating states due to manipulation of the Safety Integrated parameters after the
acceptance test
Incorrect parameter changes to Safety Integrated functions after an acceptance test can
result in unwanted motion resulting in severe injury or death.
● To prevent access to your plants and systems by unauthorized persons, implement access
● To avoid incorrect changes to the configuration and parameters of the Safety Integrated
● Check the Safety log book of SINAMICS Safety Integrated at regular intervals. Verify that
● If any changes have been made and they are intentional, repeat the acceptance test for the
11.11.1

Acceptance test structure

The test of individual Safety Integrated Functions must be carried out by an authorized person
and logged in the acceptance report. The report must be signed by the person who carried out
the acceptance test. Access rights to SI parameters must be protected by a password. This
procedure must be documented in the acceptance report - the password itself must not appear
there. Authorized in this sense refers to a person who has the necessary technical training and
knowledge of the safety functions and is authorized by the machine manufacturer to carry out
the acceptance test.
Note
Further information
● The procedure in Chapter "Acceptance test (Page 684)" is an example and a
recommendation.
● An acceptance report template in electronic format is available at your local Siemens sales
office.
Note
PFH values
The PFH values of the individual SINAMICS S120 safety components can be found at:
PFH values (PFH values (https://support.industry.siemens.com/cs/ww/en/view/76254308))
682
WARNING
restrictions and take the precautions described in the security information (see Chapter
"Safety instructions (Page 642)" and manual "SINUMERIK/SIMOTION/SINAMICS Motion
Control Industrial Security").
functions, take the precautions described in this manual.
no changes have been made to the parameters since the last acceptance test was
performed.
Safety Integrated functions affected. The purpose of the acceptance test is to ensure and
document safe operation of the plant. Correct any unintentional changes back to the
original values and repeat the acceptance test.