Function Diagrams And Parameters - Siemens SINAMICS S120 Function Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Vector control
6.9 Vdc control
Remedy
● activate the V
– Vector control: p1240 = 1 (factory setting)
– Servo control: p1240 = 1
– U/f control: p1280 = 1 (factory setting)
● Inhibit V
– Vector control: p1240 = 0
– Servo control: p1240 = 0 (factory setting)
– U/f control: p1280 = 0
● Activate the V
– Vector control: p1240 = 4 or 6
– Servo control: p1240 = 4 or 6
– U/f control: p1280 = 4 or 6
6.9.1

Function diagrams and parameters

Function diagrams (see SINAMICS S120/S150 List Manual)
● 6220
Overview of important parameters (see SINAMICS S120/S150 List Manual)
● p1240[0...n]
● r1242
● p1243[0...n]
● p1245[0...n]
● r1246
● p1247[0...n]
● p1250[0...n]
● p1251[0...n]
● p1252[0...n]
● p1254
● p1256[0...n]
● p1257[0...n]
● r1258
240
control:
dc_max
control:
dc_max
monitoring
dc_max
Vector control - Vdc_max controller and Vdc_min controller
Vdc controller or Vdc monitoring configuration
Vdc_min controller switch-on level
Vdc_max controller dynamic factor
Vdc_min controller switch-on level (kinetic buffering)
Vdc_min controller switch-on level (kinetic buffering)
Vdc_min controller dynamic factor (kinetic buffering)
Vdc controller proportional gain
Vdc controller integral time
Vdc controller rate time
Vdc_max controller automatic ON level detection
Vdc_min controller response (kinetic buffering)
Vdc_min controller speed threshold
CO: Vdc controller output
Function Manual, 06/2019, 6SL3097-5AB00-0BP2
Drive functions