4. Check the number of Motor Modules that you have set in the topology.
The braking resistors must be dimensioned for each Motor Module according to the table of
resistances above.
Figure 8-5
5. To carry out further checks, double-click ".../Drives/Drive_1 > Configuration" in the project
navigator.
A dialog opens allowing you to check the current configuration. The "Current power unit
operating values" button lists the Motor Modules according to component number. During
operation, they show the current electrical values.
Operating a parallel connection in Master/Slave mode
Motor Modules connected in parallel can also be operated in Master/Slave mode.
1. To do this, use parameter p1330 to transfer the input of the U/f characteristic to the next
power unit.
The slaves only receive the voltage setpoint for the U/f characteristic.
Drive functions
Function Manual, 06/2019, 6SL3097-5AB00-0BP2
Parallel connection of Motor Modules as Braking Modules
8.14 Motor Module as a Braking Module
Basic functions
351