Procedure
1. Click "Reset all filters" at the top right in the filter bar.
You have now re-set all configured filters. The message list then displays the unfiltered view
of the messages again.
13.3.2.2

Acknowledging faults

In order to acknowledge faults in the message list, proceed as follows:
Procedure
1. In order to acknowledge the faults being displayed, click on the "Acknowledge faults" button.
The displayed faults are acknowledged. Acknowledged faults continue to be displayed in
the message list with the
13.3.3

"Diagnostics buffer" display area

In the "Diagnostics buffer" display area, important operating events are included in the log in the
form of a logbook. The relevant data is read out from the non-volatile memory and is available
along with its history in the diagnostics buffer for the subsequent analysis of an operating fault.
Note
Detailed information on the diagnostic buffer or fault and warning buffer can be found in the
"Messages - Faults and warnings" chapter of the SINAMICS S120 commissioning manual with
Startdrive.
Displaying the diagnostic buffer
In order to call up the diagnostic buffer, proceed as follows:
Procedure
1. In the navigation, select "Diagnostics > Diagnostics buffer."
The logged events are displayed.
Note
In the "Date and time" column, the time - differing from the current drive time - is combined
from the following components: "1.1.2000 + Operating hours counter".
Drive functions
Function Manual, 06/2019, 6SL3097-5AB00-0BP2
symbol.
Web server