Siemens SINAMICS S120 Function Manual page 609

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Function of the PTC
The temperature sensor is connected to the Sensor Module at the appropriate terminals (-
Temp) and (+Temp) (see the relevant chapter in the SINAMICS S120 Control Units and
Supplementary System Components Manual). The threshold value for switching over to an
alarm or fault is 1650 Ω.
A PTC usually has a strongly non-linear characteristic, and as a consequence is used just like
a switch. When the typical rated response temperature is exceeded, then the resistance
changes abruptly (step function). The tripping resistance is ≥1650 Ohm.
● p0600 = 1 activates the motor temperature sensing using sensor 1
● p0601 = 1 sets temperature sensor type "PTC"
Function of the KTY
The temperature sensor is connected to the Sensor Module at the appropriate terminals (-
Temp) and (+Temp) (see the relevant chapter in the SINAMICS S120 Control Units and
Supplementary System Components Manual). A KTY84/1C130 temperature sensor has an
almost linear characteristic and is therefore also suitable for continuously measuring and
displaying the motor temperature.
● p0600 = 1 activates the motor temperature sensing using sensor 1
● p0601 = 2 sets temperature sensor type "KTY"
Function of the PT100/PT1000
A PT100 or PT1000 is in principle a PTC with a very linear characteristic, and is suitable for
continuous and exact temperature measurements. Not every sensor input is PT100/PT1000-
capable.
● p0600 = 1 activates the motor temperature sensing using sensor 1
● p0601 = 5 sets temperature sensor type "PT100"
or
● p0601 = 6 sets temperature sensor type "PT1000"
Function of the bimetallic NC contact
A bimetallic NC contact at a certain nominal response temperature actuates a switch. The
tripping resistance is <100 Ohm. Not every sensor input is bimetal NC contact-capable.
● p0600 = 1 activates the motor temperature sensing using sensor 1
● p0601 = 4 sets temperature sensor type "Bimetallic NC contact"
Temperature sensor type for multiple temperature channels
Set p0601 = 10 if you wish to use several temperature channels. The sensors are then
interconnected via BICO
Drive functions
Function Manual, 06/2019, 6SL3097-5AB00-0BP2
Monitoring functions and protective functions
10.2 Thermal motor protection
607