5.4

Speed setpoint filter

Function description
The "Speed setpoint filter" function allows you to hide or to attenuate certain frequency ranges.
Speed setpoint filters do not have any effect on the stability of the speed controller, because
they lie in the setpoint channel. The dynamic response in the control behavior is reduced by the
smoothing.
The various filter types are identical in structure and can be set via parameters p1415[0...n]
(Filter 1) and p1421[0...n] (Filter 2) as follows:
● Band-stop filter
● Low-pass 1st order (PT1)
● Low-pass 2nd order (PT2)
Figure 5-2
Activating and parameterizing a function
You can activate 2 speed setpoint filters in the Startdrive engineering tool via parameter
p1414[0...n].
To activate and to parameterize the speed setpoint filters, proceed as follows:
1. Select group parameter p1414[0] and open the sub categorization.
2. Select the required speed setpoint filter - and in the drop-down list of the parameter line,
select setting "[1] Yes".
Repeat this procedure for every speed setpoint filter that you wish to additionally activate.
Drive functions
Function Manual, 06/2019, 6SL3097-5AB00-0BP2
Overview: Speed setpoint filter
Servo control
5.4 Speed setpoint filter
89