Siemens SINAMICS S120 Function Manual page 641

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

● Reset password with Startdrive
– Click "Enter password" in the Startdrive secondary navigation.
– In the subsequent dialog, first enter the old password.
– Set the new password = 0.
– Click "Change password" to accept the new password.
– SINAMICS S120 responds with the message "Please change the password!"
– Close the message.
– In the "Change password" dialog box, then click the "Cancel" button.
– The password has now been reset to the default "0."
● If the safety password is no longer available, you can no longer change the safety
configuration. You then have the following options:
– To commission the SINAMICS S120 completely as new:
– To load another project into the drive (without a Safety password or with a known Safety
– If neither option is acceptable to you, please contact "Technical Support" (see "Training
Function diagrams (see SINAMICS S120/S150 List Manual)
● 2818
Overview of important parameters (see SINAMICS S120/S150 List Manual)
● p9761
● p9762
● p9763
● p10061
● p10062
● p10063
Drive functions
Function Manual, 06/2019, 6SL3097-5AB00-0BP2
- Restore the factory settings of the entire drive (Control Unit with all connected drives/
components).
- Commission the drive unit and the drives afresh.
- Commission Safety Integrated as new.
password). This is possible without a password because this operation is the same as
complete new commissioning.
and support (Page 22)").
SI Extended/Advanced Functions - parameter manager
SI password input
SI password new
SI password acknowledgment
SI TM54F password entry
SI TM54F password new
SI TM54F password confirmation
Safety Integrated Basic Functions
11.2 General information
639

Advertisement

Table of Contents
loading