Commissioning - Siemens SINAMICS S120 Function Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Important parameters (see List Manual)
Load monitoring
S p2181[D]
S p2182[D]
S p2183[D]
S p2184[D]
S p2185[D]
S ...
S p2190[D]
S p2192[D]
Speed setpoint monitoring
S p2150[D]
S p2151[C]
S p2161[D]
S r2198.4
S r2198.5
Function diagram overview (see List Manual)
S 8010
S 8013
4.2.3

Commissioning

The extended monitoring functions are activated when you are working through the
commissioning Wizard. Parameter r0108.17 indicates whether the function module
has been activated.
© Siemens AG, 2005. All rights reserved
SINAMICS S120 Function Manual, 06/05 Edition
Extended Monitoring Functions function module
Load monitoring response
Load monitoring speed threshold 1
Load monitoring speed threshold 2
Load monitoring speed threshold 3
Load torque monitoring torque threshold 1 upper
Load torque monitoring torque threshold 3 upper
Load monitoring delay time
Hysteresis speed 3
CI: Speed setpoint
Speed threshold value 3
BO: ZSW monitoring 2, |n_setp| <= p2161
BO: ZSW monitoring 2, n_setp < 0
Speed messages
Load monitoring
Extended functions
4-169