Startdrive commissioning tool
3.2 User interface - parameterization
Structure of the parameter view
The following figure shows the structure of the parameter view:
①
Secondary navigation: Limits the parameter display to the required parameter group. Applies to S120, S150, G150
and G130.
Exception: MV drive units do not use secondary navigation in the parameter view.
②
Drop-down list to restrict the parameter views:
Display standard parameters
•
Display extended parameters
•
Display service parameters
•
③
Parameter number
④
Button for comparing the parameters of the drive object to another parameter set.
In offline mode, the parameters are compared to the factory settings by default.
•
In online mode, the parameters are compared to the offline settings by default.
•
The comparison can also be disabled again.
•
⑤
Button for starting a CSV export:
Save all of the displayed parameters to a CSV file.
•
Save all of the parameters of the drive object to a CSV file.
•
⑥
Button to retentively save the parameters (Copy RAM to ROM).
⑦
Button to restore the factory settings.
⑧
Button for displaying open BICO interconnections of all of the drive objects in the offline project.
⑨
Parameter name
⑩
Value of the parameter
⑪
Unit
⑫
Data set: Indicates the data set (MDS, DDS, etc.) to which the parameter belongs.
⑬
Minimum value
⑭
Maximum value
Figure 3-7
Parameter list
38
Getting Started, 12/2018, 6SL3097-5AG30-0BP0