252
Code
Fault
(fieldbus code)
0313
UFF EOF
(0x6300)
0314
TECH LIB INTERFACE
(0x6100)
0315
RESTORE FILE
(0x630D)
0316
DAPS MISMATCH
(0x5484)
0317
SOLUTION FAULT
(0x6200)
0319
APPL LICENCE
(0x6300)
Fault tracing
Cause
UFF file structure failure
Incompatible firmware interface
Note: This fault cannot be
reset.
Restoration of backed-up
parameters failed.
Mismatch between firmware
version (in JMU) and power unit
logic versions.
Fault generated by function
block SOLUTION_FAULT in the
application program.
Drive power unit (JPU) lacks the
correct application licence
required to use the downloaded
application program.
What to do
Contact your local ABB representative.
Contact your local ABB representative.
Contact your local ABB representative.
The fault is reset after a successful
restoration via the control panel or
DriveStudio.
Contact your local ABB representative.
Check the usage of the SOLUTION_FAULT
block in the application program.
Assign the correct application licence to the
drive power unit using the DriveSPC PC tool
or remove the protection from the application
used.
For more information, see section
program licensing and protection
Application
on page 32.