The parameter "IQMEM" for selecting the shared memory extended function is 16bit data. Set the bit 0 to
one to use the extended functions (monitoring, operation functions). Set the bit 1 to one to use the
sequencer direct performance function. Both bits can be set to one.
For information on how to set up a parameter, refer to Supplement volume "Instruction Manual, Detailed
Description of Functions and Operations."
Parameter
Select shared
memory extended
function
To use the shared memory extended functions and sequencer direct performance functions, set each bit as
follows:
Use the shared memory extended function
Use the sequencer direct performance function
When using the sequencer direct performance function, robot's internal memory is extended as follows:
Robot controller's internal memory
Sequencer direct performance is invalid:
Extend and delete
external program
variable
Extend and delete
system state
variable
CAUTION
2-9Operation flow
Array Qty
Parameter
Character
Name
Qty
IQMEM
1 digit inte-
ger
External program
Set both bits 0, 1 of
variable
parameter IQMEM to 1
Set either bit 0, 1 of
parameter IQMEM to 0
System state
Set both bits 0, 1 of
variable
parameter IQMEM to 1
Set either bit 0, 1 of
parameter IQMEM to 0
When the sequencer direct performance function is valid, external program variable
and system state variable areas are extended in the robot controller (extended vari-
ables). When the function gets invalid, the extended variable area is cleared. Conse-
quently, after the sequencer direct performance function was enabled once, the
robot location was taught, and the data was set, when the parameter is turned back,
be aware that the previous teaching and setting data will disappear.
Description
Set validity (1)/ invalidity (0) for the function.
Sets each bit by allocating a function to each bit.
0000000000000000 bit2-15: Not used
|+- bit0: Use the shared memory
extended function
+-- bit1: Sequencer direct
performance function
Bit 1
Bit 0
0
1
1
1
Sequencer direct performance is valid:
External program
variable
External program
variable for
sequencer direct
performance
(For instructing
robot location)
+
System state
variable
+
System state
variable for
sequencer direct
performance
Factory Default
0000000000000000
Extend external
program variable
Extend system state
variable

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cr750-q seriesCr751-q seriesCrnq-700 series

Table of Contents