■ Serial Communication (PC selected, default settings)
Control items
(1) Read settings
a. LED1 to 4 cumulative data (irradiation period and number of irradiation times
b. Status (READY, BUSY1 to 4, WARNING and ERROR)
(2) Read and write settings
a. Type setup data (10)
c. Start signal (pulse/status)
e. Type setting (10)
g. LED head fine adjustment (4)
(3) Online data read (automatic mode/manual mode)
a. Pattern No., Step No. (automatic) b. Irradiation time (automatic)
c. Alarm temp. display (auto., man.) d. Replacement remaining time (auto., man.)
e. Error No. (auto., man.)
g. Cumulative no. of irrad. times
i. LED head status (auto., man.)
(4) Online operation
a. Automatic start (4)
c. Manual LED selection (4)
e. Manual start/stop
(5) PC file management: Data managed by attaching file names to a. through
h. of (2), above (when using utility software).
■ Utility Software (PC-side operation software)
・Software can be downloaded from the Web site.
・Supports Windows 95/98/XP
Since item control and set data can be copied (file management), the same settings can be easily
written to multiple units.
Aicure PC operation screen
Serial Communication
b. Pattern setup data (10)
d. Irradiation setting (MULTI/ALL)
f. Busy signal (for a and b)
h. Manual intensity (4)
f. Cumulative irradiation time (auto., man.)
h. READY signal (automatic)
b. Automatic stop (4)
d. Manual intensity setting (4)
f. Abnormal reset