28 Start-up and controls

Editing pump parameters

The parameters 6001...6019 are user adjustable parameters to control the pump
operation. The below steps explain the editing of inverter start voltage and inverter reset
time. Similarly, edit the other pump parameters in this group.
Step
Description
Setting inverter starting voltage
1
Select 60 PUMP CONTROL
with the UP/DOWN keys and
press SEL.
2
Select parameter 6003
START DC VOLT with the
UP/DOWN keys. Press EDIT
to change the parameter
value.
You can edit the minimum DC
voltage to start the inverter.
Note: If you change this value
while the inverter is running,
the changed value is effective
only during the next start.
3
Press the UP/DOWN keys to
change the parameter value
and press SAVE to store the
modified value or press
CANCEL to leave the set
mode. Any modifications not
saved are cancelled.
Press EXIT to return to the
listing of parameter groups,
and again to return to the
main menu.
Keys
Control panel
PA R GROU PS
R E M
60 PUMP CONTROL
61 FLOW CALCULATION
98 OPTIONS
99 START-UP DATA
01 OPERATING DATA
EXIT
PA RA ME TERS
R E M
6001 AUTO/MANUAL SEL
6002 MANUAL START CMD
6003 START DC VOLT
6004 PV CELL MIN VOLT
EXIT
PA R E DIT
R E M
6003 START DC VOLT
C A N C E L
60
00:00
SEL
250 V
00:00
ED IT
250 V
00:00
SAVE