PROFINET IO operation

3.6.3.1

What do you have to set for communication via PROFINET?

Check the communication settings using the following table. If you answer "Yes" to the
questions, you have correctly set the communication settings and can control the inverter via
the fieldbus.
Questions
Is the inverter correctly connected to the bus net-
work?
Do the IP address and device name in the inverter
and control match?
Is the same telegram set in the inverter the same as
in the higher-level control?
Are the signals that the inverter and the control
exchange via PROFINET correctly interconnected?
Communication with the control, even when the line voltage is switched off
If, in your plant or system, communication with the control system should continue to function
even when the line voltage is switched off, then you must externally supply the
inverter/Control Unit with 24 V DC. To do this, use terminals 31 and 32 – or connector X01.
You can find additional details in the operating instructions for the inverter or the Control
Unit.
3.6.3.2

Configuring communication to the control

Configuring the communication using SIMATIC S7 control
If the inverter is not included in the hardware library, you have the following options:
● Install the most up to date Startdrive version
● Install the GSDML of the inverter using "Options/Manage general station description
(GSD)" in the components catalog.
Configuring the communication using a non-Siemens control
1. Import the device file (GSDML) of the inverter into the engineering tool for your control
system.
2. Configure the communication.
Fieldbuses
Function Manual, 04/2018, FW V4.7 SP10, A5E34229197B AE
Communication via PROFIBUS and PROFINET
3.6 Communication via PROFINET
Answer/description
Integrating inverters into PROFINET
(Page 62)
Configuring communication to the
control (Page 63)
Setting the telegram in the control
Interconnect signals in the inverter in conform-
ance with PROFIdrive.
PROFIDRIVE profile - Cyclic communi-
cation (Page 17)
PROFIDRIVE profile - Acyclic commu-
nication (Page 42)