6.1 Alarms and diagnostics
There are different sources to get information about both the operating state of the convertor
(either in the presence of alarms or not) and the various causes that have brought the system
in alarm/ stop condition.
As already stated in the previous chapter, 4 alarm states of the convertor are available on the
digital outputs of terminal board J1; some information is available using the keyboard while
other information, not necessarily different, can be derived from the 7-segment display on the
front of the convertor.
6.1.1 Visualization and codifying of alarms on the keyboard
Hereafter you will find a table where the different visualizations of memorized alarms are
listed, together with the corresponding number which appears on the 7-segment display.
Moreover, you can see the various messages that appear cyclically when one or more alarms
are memorized (the first line of the alphanumerical display blinks). lf various alarms are
memorized, the message which appears is referred to the alarm with highest priority: it
increases with the increasing of the number, except for I
Description
Thermal probe drive
Thermal probe motor
(when connected)
Resolver failure
Overbraking
Overvoltage
Brake fault
Power fault
Undervoltage
2
I
t protection
Limit switch
MANIU04.9607 GB 03/97
CHAPTER 6 - ALARM CODIFYING
Codifying
Visualization
0000000001
<<< ALARM 1! >>>
F987654321
Drive thermal probe
0000000010
<<< ALARM 2! >>>
F987654321
Motor thermal probe
0000000100
<<< ALARM 3! >>>
F987654321
Resolver failure
0000001000
<<< ALARM 4! >>>
F987654321
Overbraking
0000010000
<<< ALARM 5! >>>
F987654321
0000100000
<<< ALARM 6! >>>
F987654321
0001000000
<<< ALARM 7! >>>
F987654321
0010000000
<<< ALARM 8! >>>
F987654321
Undervoltage
0100000000
<<< ALARM 9! >>>
F987654321
I
1000000000
<<< ALARM 10! >>>
F987654321
2
t and limit switch alarms.
Display
Overvoltage
Brake fault
Power fault
2
t protection
Limit switch
1
2
3
4
5
6
7
8
9
F
Page 6.1