Configuring the PG 720
"Boot Sequence"
The following submenu appears when you select the "Boot Sequence" field
Field
in the main menu:
Figure 6-5
Boot sequence
SETUP prompt
POST Errors
Floppy check
Summary screen The most important system parameters are output on the display at
6-10
PhoenixBIOS Note BIOS 4.0 Setup-Copyright 1985-95 Phoenix Technologies Ltd.
Main
Advanced
Security
Power Savings Exit
Boot Options
Boot sequence:
[A: then C:]
SETUP prompt:
[Enabled]
POST errors:
[Enabled]
Floppy check:
[Enabled]
Summary screen:
[Enabled]
F1
Help
Select Item
– / +
ESC
Exit
Select Menu
Enter Select
"Boot Options" Submenu
Here you can define the device sequence from which a system start
(boot attempt) is to be carried out first.
A: then C:
C: then A:
C: only
During the system loading phase, a message at the bottom of the
screen tells you how to activate the Setup program. In Disabled
mode, this message is not displayed.
The loading procedure is aborted if an error is detected during the
system loading phase and an error message appears.
In Disabled mode, errors which occur during the system loading
phase are ignored.
During the system loading phase, the floppy head is moved by a
number of steppings to the inside, and then back again. This test is
useful because the drive is initialized again in the process.
the end of the system loading phase.
Item Specific Help
Order system searches drives
for a boot disk.
Change Values
F9
Setup Defaults
Sub-Menu
F10
Previous Values
First from floppy A: then from drive C:
First from drive C: then from floppy A:
Only from drive C:
PG 720 P Programming Device
C79000-G7076-C721-02