APPENDICES
No.
Name
3
Cyclic transmission stop
SB004E
acknowledgment status
(78)
(host)
3
Cyclic transmission stop
SB004F
completion status
(79)
(host)
3
Cyclic transmission start
SB0050
acknowledgment status
(80)
(system)
3
Cyclic transmission start
SB0051
completion status
(81)
(system)
3
Cyclic transmission stop
SB0052
acknowledgment status
(82)
(system)
3
Cyclic transmission stop
SB0053
completion status
(83)
(system)
SB0054
Parameter receive status
(84)
SB0055
Received parameter error
(85)
3
SB0056
Communication status
(86)
SB0057
Parameter type
(87)
Operation designation at
fault of control station
SB0058
(88)
Operation designation at
fault of (multiplexed)
remote master station
SB0059
Low-speed cyclic
(89)
designation
SB005A
Parameter type 2
(90)
SB005B
END asynchronous
(91)
settings
SB005C
I/O master station
(92)
(Block 1)
3: Valid only when the SB0047 is off. When it turns on (error), the last data are retained.
App - 11
Table 3 Link special relay (SB) list (continued)
Description
Indicates the stop acknowledgment status of the cyclic
transmission.
Off: Not acknowledged (SB0001 is off)
On: Stop acknowledged (SB0001 is on)
Indicates the stop completion status of the cyclic transmission.
Off: Not completed (SB0001 is off)
On: Stop completed (SB0001 is on)
Indicates the startup acknowledgment status of the cyclic
transmission.
Off: Not acknowledged (SB0002 is off)
On: Start acknowledged (SB0002 is on)
Indicates the completion status of the cyclic transmission.
Off: Not completed (SB0002 is off)
On: Start completed (SB0002 is on)
Indicates the stop acknowledgment status of the cyclic
transmission.
Off: Not acknowledged (SB0003 is off)
On: Stop acknowledged (SB0003 is on)
Indicates the stop completion status of the cyclic transmission.
Off: Not completed (SB0003 is off)
On: Stop completed (SB0003 is on)
Indicates the parameter receive status.
Off: Receive completed
On: Not received
Indicates the status of the received parameters.
Off: Parameters normal
On: Parameters abnormal
Indicates the status of the transient transmission
Off: Transient transmission by the control station
On: Transient transmission by the sub-control station
Indicates the parameter type.
Off: MELSECNET/10 parameter
On: MELSECNET/H parameter
On PLC to PLC network
Indicates the setting of "With data link by sub control station
when control station is down."
Off: Cyclic transmission made by sub control station when
control station fails.
On: Cyclic transmission not made by sub control station
when control station becomes faulty
On remote I/O network
Indicates the status of designating cyclic transmission when the
(multiplexed) remote master station fails.
Off: Cyclic transmission made by multiplexed remote sub-
master station when multiplexed remote master station
fails (multiplexed remote I/O network)
On: Cyclic transmission not made when remote master
station fails (remote I/O network)
Indicates whether or not there are any parameter settings for the
low-speed cyclic transmission.
Off: No settings
On: Settings exist
Indicates the parameter type of the control station.
Off: MELSECNET/10 mode, MELSECNET/H mode
On: MELSECNET/H Extended mode
Indicates the END asynchronous settings status of the remote
I/O network.
Off: END asynchronous settings disabled
On: END asynchronous settings enabled
Indicates the I/O master station setting (Common parameter
setting) of block 1. (Valid when SB0049 is OFF)
Off: No setting
On: Setting exists. (Station No. is stored in SW005C.)
Use permitted/prohibited
Control
Normal
station
station
Loop
Bus
Loop
Bus
[Availability column] Loop: optical loop, Bus: coaxial/twisted bus
MELSEC-Q
Remote
Remote I/O
master
station
station
Loop
Bus
Loop
Bus
: Available,
: Not available
App - 11