3
SPECIFICATIONS
CPU type
Q00UJ/Q00U/Q01UCP
Q02UCPU
Q03UD/Q03UDECPU
Q04UDH/Q04UDEH/
Q06UDH/Q06UDEH/
Q10UDH/Q10UDEH/
Q13UDH/Q13UDEH/
Q20UDH/Q20UDEH/
Q26UDH/Q26UDEH/
Q50UDEH/Q100UDEHCPU
Q03UDV/Q04UDV/Q06UDV/
Q13UDV/Q26UDVCPU
3 - 41
(b) Data link transfer time required for transferring data of all
the set points
α
= KM7×
L1
 L1 : Data link transfer time taken to transfer all the set points of data
LB
: Total number of link relay (LB) points set in interlink transmission
T
parameters
LW
: Total number of link register (LW) points set in interlink transmission
T
parameters
KM7: Constants
Source (main base)
Source (main base)
Target (main base)
Target (extension base)
25.00
25.00
22.10
22.10
22.10
LB
T
+LW
[ms]
T
16
-3
KM7( 10
)
Network module mounting position
Source (extension base)
Target (main base)
25.20
25.20
22.50
22.50
22.50
MELSEC-Q
Source (extension base)
Target (extension base)
25.20
25.50
25.20
25.50
22.70
23.00
22.70
23.00
22.70
23.00