GE UR Series Instruction Manual page 401

Line differential relay
Hide thumbs Also See for UR Series:
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 37 of 38)
ADDR
REGISTER NAME
F821
Distance I2Za Angle
F822
Distance I2Zb Angle
F823
Distance I2Zc Angle
F824
Distance Alpha IabZ Vab Angle
F825
Distance Alpha IbcZ Vbc Angle
F826
Distance Alpha IcaZ Vca Angle
F827
Distance Alpha IagZ Vag Angle
F828
Distance Alpha IbgZ Vbg Angle
F829
Distance Alpha IcgZ Vcg Angle
F82A
Distance IabZR Vab IabZR Angle (4 items)
F82E
Distance IbcZR Vbc IbcZR Angle (4 items)
F832
UNDEFINED (4 items)
F836
Distance IabZR Vab IabZR Angle (4 items)
F83A
Distance IbcZR Vbc IbcZR Angle (4 items)
F83E
Distance IcaZR Vca IcaZR Angle (4 items)
F842
Distance IagZR Vag IagZR Angle (4 items)
F846
Distance IbgZR Vbg IbgZR Angle (4 items)
F84A
Distance IcgZR Vcg IcgZR Angle (4 items)
F84E
Distance IagZL Vag IagZL Angle (4 items)
F852
Distance IbgZL Vbg IbgZL Angle (4 items)
F856
Distance IcgZL Vcg IcgZL Angle (4 items)
Modbus File Transfer Area 2 (Read/Write)
FA00
Name of file to read
Modbus File Transfer Area 2 (Read Only)
FB00
Character position of current block within file
FB02
Size of currently-available data block
FB03
Block of data from requested file (122 items)
Neutral Overvoltage (Read/Write Grouped Setting) (3 modules)
FC00
Neutral OV X Function
FC01
Neutral OV X Signal Source
FC02
Neutral OV X Pickup
FC03
Neutral OV X Pickup Delay
FC04
Neutral OV X Reset Delay
FC05
Neutral OV X Block
FC06
Neutral OV X Target
FC07
Neutral OV X Events
FC08
Neutral OV Reserved (8 items)
FC10
...Repeated for module number 2
FC20
...Repeated for module number 3
Auxiliary Overvoltage (Read/Write Grouped Setting) (3 modules)
FC30
Auxiliary OV X Function
FC31
Auxiliary OV X Signal Source
FC32
Auxiliary OV X Pickup
FC33
Auxiliary OV X Pickup Delay
FC34
Auxiliary OV X Reset Delay
FC35
Auxiliary OV X Block
FC36
Auxiliary OV X Target
FC37
Auxiliary OV X Events
FC38
Auxiliary OV X Reserved (8 items)
FC40
...Repeated for module number 2
FC50
...Repeated for module number 3
Auxiliary Undervoltage (Read/Write Grouped Setting) (3 modules)
FC60
Auxiliary UV X Function
FC61
Auxiliary UV X Signal Source
GE Power Management
Table B–9: MODBUS MEMORY MAP (Sheet 38 of 38)
RANGE
ADDR
REGISTER NAME
-180 to 180
FC62
Auxiliary UV X Pickup
-180 to 180
FC63
Auxiliary UV X Delay
-180 to 180
FC64
Auxiliary UV X Curve
-180 to 180
FC65
Auxiliary UV X Minimum Voltage
-180 to 180
FC66
Auxiliary UV X Block
-180 to 180
FC67
Auxiliary UV X Target
-180 to 180
FC68
Auxiliary UV X Events
-180 to 180
FC69
Auxiliary UV X Reserved (7 items)
-180 to 180
FC70
...Repeated for module number 2
-180 to 180
FC80
...Repeated for module number 3
-180 to 180
-180 to 180
-180 to 180
-180 to 180
-180 to 180
-180 to 180
-180 to 180
-180 to 180
-180 to 180
-180 to 180
-180 to 180
---
0 to 4294967295
0 to 65535
0 to 65535
0 to 1
0 to 5
0 to 1.25
0 to 600
0 to 600
0 to 65535
0 to 2
0 to 1
0 to 65535
0 to 1
0 to 5
0 to 3
0 to 600
0 to 600
0 to 65535
0 to 2
0 to 1
0 to 65535
0 to 1
0 to 5
L90 Line Differential Relay
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
°
0.01
F002
°
0.01
F002
°
0.01
F002
°
0.01
F002
°
0.01
F002
°
0.01
F002
°
0.01
F002
°
0.01
F002
°
0.01
F002
°
0.01
F002
°
0.01
F002
°
0.01
F002
°
0.01
F002
°
0.01
F002
°
0.01
F002
°
0.01
F002
°
0.01
F002
°
0.01
F002
°
0.01
F002
°
0.01
F002
°
0.01
F002
---
---
F204
---
1
F003
---
1
F001
---
1
F001
---
1
F102
---
1
F167
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F102
---
1
F167
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F102
---
1
F167
DEFAULT
RANGE
0
0 to 3
0
0 to 600
0
0 to 1
0
0 to 3
0
0 to 65535
B
0
0 to 2
0
0 to 1
0
0 to 65535
0
0
0
0
0
0
0
0
0
0
0
0
0
(none)
0
0
0
0 (Disabled)
0 (SRC 1)
300
100
100
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
300
100
100
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
B-45

Advertisement

Table of Contents
loading

This manual is also suitable for:

L90