Siemens SINUMERIK 840D sl Manual page 44

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Structure of the drive group
2.6 Heat Dissipation of the Control Cabinet
Table 2-2
Ventilation clearances above and below the components
Component
CU320
SMCxx
TM15
TM31
TM41
Line filter for Line Module
5 kW - 120 kW
Line reactor for Active Line Module
16 kW – 120 kW
Line reactor for Smart Line Module
5 kW – 36 kW
Active Line Module
16 kW – 55 kW
80 kW – 120 kW
Smart Line Module
5 kW – 36 kW
Motor Module < 132 A
Motor Module
132 A and 200 A
Braking Module
Control Supply Module
Capacitor Module
The specifications regarding ventilation clearances for two-tier configurations are provided in
Drive Line-Up.
2-24
Order No.
6SL3040-0MA00-0AAx
6SL3055-0AA00-5xAx
6SL3055-0AA00-3FAx
6SL3055-0AA00-3AAx
6SL3055-0AA00-3PAx
6SL3000-0BExx-xAAx
6SN1111-0AA00-xxAx
6SL3000-0CExx-0AAx
6SL3130-7TExx-xAAx
6SL3130-7TExx-xAAx
6SL3130-6AExx-0AAx
6SL312x-1TExx-xAAx
6SL312x-1TE3x-xAAx
6SL3100-1AE31-0AAx
6SL3100-1DE22-0AAx
6SL3100-1CE14-0AAx
Clearance [mm]
80
50
50
50
50
100
100
100
80
80 (additional 50 in front of fan)
80
80
80 (additional 50 in front of fan)
80
80
80
Guide for the SINUMERIK 840D sl machine configuring
Manual, 07/2006 Edition, 6FC5397-6CP10-0BA0