Connection of the Components
5.3 Line Modules Interfaces Description
Warning
For operation, ground must be attached to the -X21:3 24 VDC terminals and the -X21:4
terminals. For cancelation, a pulse suppression will be activated. Feedback is deactivated
and the bypass relay drops out. If the Line Module is not separated from the supply system
when the EP terminal is opened (e.g. no main power switch present), the DC link will remain
charged.
Notice
If the main power switch is used to switch off a running drive group, the voltage at terminal 3
(EP +24 V) and 4 (EP M) must be interrupted beforehand. This can be achieved, for
example, with a leading (≥10 ms) disconnecting auxiliary contact.
5.3.2.5

Active Line Module X24 24 V Terminal Adapter

Table 5-4
X24 terminal block
Terminal
+
M
The 24 V terminal adapter is supplied as standard
Max. connectable cross-section: 6 mm
Type: Screw terminal 5
5-20
Designation
24 V supply
Chassis ground
2
Technical data
24 VDC supply voltage
Electronics ground
(tolerance limit 20.4 VDC to 28.8 VDC, voltage
interruption for 3 ms without function impairment).
Used for the central infeed of the 24 VDC power supply
of the drive group