X200-X203 Drive-Cliq Interface; Meaning Of The Leds On The Motor Module - Siemens SINUMERIK 840D sl Manual

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Connection of the Components
5.4 Motor Modules Interface Description
5.4.5

X200-X203 DRIVE-CLiQ interface

Table 5-15
DRIVE-CLiQ interface X200-X202: Single Motor Module
DRIVE-CLiQ interface X200-X203: Double Motor Module
Pin
1
2
3
4
5
6
7
8
A
B
Blanking plate for DRIVE-CLiQ interface: Molex, order number: 85999-3255
5.4.6

Meaning of the LEDs on the Motor Module

Table 5-16
Meaning of the LEDs on the Motor Module
LED
Color
-
Green
Orange
Red
Green
READY
Red
Green/ Orange
or Red/Orange
-
Orange
DC LINK
Red
5-36
Name
TXP
TXN
RXP
Reserved, do not use
Reserved, do not use
RXN
Reserved, do not use
Reserved, do not use
+ (24 V)
GND (0 V)
State
Description
Off
Electronics power supply outside the permissible tolerance range.
Steady light
The component is ready for operation and cyclic DRIVE-CLiQ
communication is taking place.
Steady light
DRIVE-CLiQ communication is being established.
Steady light
At least one fault is present in this component.
Flashing
Firmware is being downloaded.
2 Hz
Flashing
Component recognition via LED is activated (p0124).
2 Hz
Note:
Both options depend on the LED status when module recognition is
activated via p0124 = 1.
Off
Electronics power supply outside the permissible tolerance range.
Steady light
DC link voltage within permissible tolerance range (only when ready
for operation)
Steady light
DC link voltage outside permissible tolerance range (only when ready
for operation)
Technical specifications
Transmit data +
Transmit data -
Receive data +
Receive data -
Power supply
Electronic ground
Guide for the SINUMERIK 840D sl machine configuring
Manual, 07/2006 Edition, 6FC5397-6CP10-0BA0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics s120